Ajax FireProtect 2 Heat Alarm

£111.50

(£92.92 ex VAT)

sku: AJAX-FIREPROTECT2-RB-HEAT

This battery-powered FireProtect 2 detects heat and sounds an alarm locally. Heat detection is useful where smoke from normal activity makes a smoke detector unsuitable, subject to the installation design.

A compatible hub is optional for app and system functions. Correct positioning and maintenance remain essential.

Colour

model

Keys Supplied: per lock ( total) total (unless ordering multiple groups)
Additional Keys are available below
Qty:

Shipping From:

When ordering multiple Keyed Alike locks, only 1 set of keys are provided as all additional locks are made to work from that key.

If ordering 4 or more keyed alike locks you can have them set up as different groups. If Required: Let us know the details in the "Specific Key Requirements" field above.

Each group of locks will then receive keys.

Ajax FireProtect 2 Heat Alarm

Ajax Residence Line

Heat sensing. For the rooms that need it.

Inside the alarm. Local warning, optional connection.

The detector has its own sounder and can detect its specified hazards without being paired to an Ajax hub. Adding a compatible hub provides app notifications and supported system functions. Standalone operation does not automatically make separate detectors an interconnected system.

Let the other alarms know. Interconnection needs commissioning.

With primary interconnection enabled, a detector sends an alarm to the hub, which starts the other configured fire sounders. Compatible FireProtect 2 units can also support a fallback radio alarm between detectors if the hub link is lost. Fallback requires firmware 5.59.2.xx or later, the marked supporting hardware and proper setup. Do not assume separate unpaired detectors automatically interconnect.

Battery or mains power? Plan around the installation.

These models both detect heat, not smoke. Battery-powered RB/SB models avoid a mains connection; the AC model needs an electrician and a suitable mains circuit. The installation design determines which is appropriate.

Scroll across if needed to compare prices and specifications.

Product prices and specifications. Configurable products show family options and starting prices.

Ajax FireProtect 2 Heat Alarm

View product

Ajax FireProtect 2 AC (Heat) Jeweller

View product
Price Including VAT From £111.50From £88.75
Detection
  • Heat
  • Heat
Power supply
  • RB: 2 x CR123A replaceable batteries. SB: 2 sealed lithium batteries.
  • 110-240 V AC, 50/60 Hz, with a non-replaceable backup battery
Size (W x H x D)
  • 86 x 86 x 44 (mm)
  • 122 x 122 x 54 (mm)

Heat detection where smoke is not the right signal.

Two thermistors monitor for an excessive temperature and a rapid rise in heat. A heat-only detector can be appropriate where normal cooking fumes make smoke detection unsuitable, subject to the installation design. It does not detect smoke or carbon monoxide and must not replace the smoke alarms required elsewhere.

Kitchen

Optional connected protection. Add the roles you need.

The detector can warn locally without a hub. Hub 2 Plus adds supported app and system functions. ManualCallPoint Red is a separate, hub-dependent way to raise an alarm manually; it does not detect smoke, heat or carbon monoxide.

What you need. Fitting and setup.

No mains cable is required. RB models use two replaceable CR123A batteries; SB models have sealed batteries and the complete detector must be replaced when they are depleted. Follow the selected model's positioning, testing and replacement instructions. For a hub-connected installation, check Battery Life Optimization and commission the radio link and interconnection. Check the detector type, siting and coverage against the product instructions and the requirements for your property. Seek specialist advice if you are unsure.

Part Size (mm)
width 86
Height 86
Depth 44

Brand

SKU

AJAX-FIREPROTECT2-RB-HEAT

Network Connection

Jeweller when paired with a compatible hub; standalone local alarm supported

Power Supply

RB: 2 x CR123A replaceable batteries. SB: 2 sealed lithium batteries.

Enclosure Protection

IP20

Detection

Heat

Radio Range

Up to 1,700 m in open space

Alarm Volume

85 dB at 3 m

Hub Requirements

Optional for local alarm; required for app and configured system functions

Operating Temperature

0 to +50 C

FAQs

No. This FireProtect 2 can detect its specified hazards and sound locally without a hub. A compatible hub adds app notifications and configured system functions. Do not assume separate unpaired alarms automatically interconnect.

No. This model does not have a smoke sensor. A separate suitable smoke alarm is needed wherever the installation design requires smoke detection.

Yes. This version is battery powered. Follow the selected model instructions for siting, testing and battery or end-of-life replacement.

A compatible Ajax hub adds remote status and app notifications. The hub needs a working configured connection to Ajax Cloud for remote alerts.

SmartBracket secures the battery-powered detector without mains or network cabling. Check the exact siting and spacing instructions for this sensor type.

Use the Test/Mute button and inspection procedure in the manual. Act on low-battery, fault and end-of-life warnings rather than assuming a silent alarm is healthy.